Free Cloud, no subscriptionShips within 3 working daysOrder →

Home / Guides

First start of Sunsynk Monitor: what each screen is telling you

A new Sunsynk Monitor goes through three screens before it shows a single watt: Wi-Fi setup, search, then the values. Each carries a short message in English. This guide translates them and says what to do when the box stops at one of them.

By the Sunsynk Monitor team · 23 November 2026 · 4 min read

In short

  • RJ45 cable into the RS485 socket of the inverter, then USB-C power: in that order.
  • WIFI SETUP means the box is waiting for a network. A phone, the SunsynkMonitor network and the page shown on the screen are all you need.
  • On the search screen, the yellow line is the one to read. “No answer” sends you to the socket, the “485 / Slave” setting and the address.

Unpack and plug in

You should find the Sunsynk Monitor box, an RJ45 cable for the inverter and a USB-C cable. A charger is not included: use a phone charger. Start with the data cable. One end goes into the box, the other into the RS485 socket of the inverter, the one used for monitoring. The BMS socket, already taken by the battery, and the meter and parallel sockets are not the right ones. Then connect the USB-C cable to the charger.

Screen one: WIFI SETUP in red

The box cannot know your Wi-Fi yet, so it starts a small network of its own and uses the screen as a note to you.

  1. 1. On your phone, join the WiFi network, with the network name underneath. It reads SunsynkMonitor- and four characters. No password is asked.
  2. 2. Open this page:, followed by a short web address. Copy it into your phone browser.
  3. 3. Pick your home WiFi and press Save. The page lists the networks the box can hear. Take your own, give its password and press Save.
Sunsynk Monitor screen in WIFI SETUP mode: three numbered instructions, the SunsynkMonitor network and a web address
Screen one. The orange lines are the network to join and the address to type.

Two remarks. The network must be a 2.4 GHz one, as the page itself reminds you. And the last line of the screen, No WiFi saved yet, is not an error: it only says that no network has been stored so far.

Once saved, the box restarts by itself and connects. If the password was mistyped, it cannot connect: after roughly forty seconds the SunsynkMonitor network reappears and the screen is back on WIFI SETUP, this time ending with Cannot join: and your network name. Go through the three steps once more.

Screen two: Looking for the inverter

Connected to Wi-Fi, the box shows what it is doing on the inverter side. Below Looking for the inverter, a yellow line gives the current state and a counter shows the answers received so far, 0 replies ok to begin with. The screen also carries a fixed reminder, RS485 port, set to 485 / Slave on the inverter.

Sunsynk Monitor screen while searching: Looking for the inverter, the yellow No answer line and the reply counter at 0
Screen two when nothing replies: the yellow line starts with “No answer”.

The yellow line can read:

  • Starting: the first moments after power-up.
  • Searching: address 1 (or another number): the box is calling the inverter at this address. It tries the one saved in its settings and then 1 to 4 in turn.
  • Trying other RJ45 pins: on boxes that can do it, a change of socket arrangement made by the box after an unsuccessful round. No action needed.
  • No answer: check port, then swap A/B: no address replied. On the screen only the beginning fits, up to “check port, th”. The box waits fifteen seconds and searches again, over and over.
  • This inverter type is not supported (also cut short on the screen): something answered, but it is a micro or string inverter, not a hybrid the box can read.

What to check on “No answer”

Begin with the socket, because it is the usual culprit: BMS, meter and parallel sockets look the same as the RS485 one. Next comes the inverter setting named on the screen. The RS485 port has to be on 485 / Slave. Then the address: the box page calls it “Modbus SN”, after the name used by the inverter, and expects 1 unless yours was changed (0 is never valid). You can enter another value under Settings on the box page, then press “Search again”. To reach that page, type the address shown at the bottom of the screen into a browser on the same Wi-Fi.

As for “swap A/B”, it concerns home-made cables. If you use the cable from the parcel, ignore it.

Screen three: your figures

The first good answer replaces the search screen with the live view. Big on the left, the battery percentage and its gauge, with volts and amps beneath. On the right, in this order: solar production, house consumption, battery power (plus for charge, minus for discharge) and grid power, in W or in kW with a “k”. The header shows ON GRID, OFF GRID or, if the inverter reports a fault, FAULT. The foot of the screen gives grid voltage and inverter temperature.

Do not be surprised when it changes: every twelve seconds the box shows TODAY for six seconds, a summary of the day in kWh for solar, load, battery charge and discharge, and grid. Then the live view returns.

Running without Wi-Fi

With the latest firmware the box still does its job on the screen. It alternates every ten seconds between your figures and the WIFI SETUP note, which is normal and not a fault. One limit to know: with no Wi-Fi, the search screen is skipped, so a box that has not found the inverter shows WIFI SETUP only.

The little light

It gives the same information as the search screen, from a distance. A flash every two seconds: readings are coming in. Quick continuous blinking: the inverter is not answering.

When to write to us

If the yellow line has said “No answer” for several minutes after these checks, contact us. Attach a photo of the box screen and the report from the box page: Diagnostics tab, “Download report”.

We may suggest reinstalling the firmware. You can do it yourself on this page from a computer, using Chrome or Edge and a USB-C cable able to carry data. All settings are erased in the process, the Wi-Fi included, so the box will greet you with WIFI SETUP again.

Common questions

Is “No WiFi saved yet” an error message?

No. It appears on the WIFI SETUP screen of any box that has not been given a network yet.

What does “Cannot join:” followed by my network name mean?

The box tried the saved network and could not connect, most often because of the password, sometimes because the router is off or out of range. Redo the three steps on the screen.

The message is cut off on the screen. Where can I read it in full?

On the page of the box, at the address shown at the bottom of the screen. The complete text is “No answer: check port, then swap A/B”.

Do I need Wi-Fi for the box to read my inverter?

No. Without Wi-Fi the screen still shows the figures, alternating with the setup instructions. Wi-Fi adds the page on your phone, Home Assistant and the Cloud.

Can I reinstall the firmware from a phone?

No. It takes a computer with Chrome or Edge and a USB-C data cable.

Sunsynk Monitor box with its colour screen showing solar, battery and grid figures from a Sunsynk inverterRS485 RJ45 socket and USB-C power input of Sunsynk Monitor
The Sunsynk Monitor box, real photos. Size, ports and specifications →
Hands-on

See it on your own system

See your Sunsynk system second by second

Order Sunsynk Monitor now. We prepare and test it for your exact Sunsynk model, and it leaves within 3 working days.

Plug & play: working in about a minute

Order for €59Ships within 3 working days · free cancellation until dispatch
Follow us on FacebookTips, news and real installations from our customers.
Follow