In short
- Most codes describe a condition outside the inverter: no grid, a battery at its limit, too much load, too much heat.
- Many clear on their own once the cause has gone; a code that comes back daily has a pattern worth finding.
- Insulation, DC and arc faults involve the roof wiring: leave those to a qualified installer.
Sunsynk hybrids number their alarms with an F and two digits. The list is long, but a handful of codes cover most of what happens in a house. The names below follow the fault table of the Sunsynk hybrid manuals; wording moves a little between models and firmware, so keep the manual for your exact model at hand.
The codes you are most likely to see
| Code | Meaning | Look at first |
|---|---|---|
| F13 | Working mode changed | Someone changed the system mode, grid type or a battery setting. |
| F18 | AC overcurrent (hardware) | A motor start or a short on the load side. |
| F20 | DC overcurrent (hardware) | Battery or PV current peak; often a battery side problem. |
| F23 | AC leakage current | An appliance or wiring fault leaking to earth. |
| F24 | DC insulation impedance | Damp or damaged PV cabling, frequent on wet mornings. |
| F35 | No AC grid | Power cut, grid breaker off, loose grid connection. |
| F56 | DC bus voltage too low | Battery at its low limit, or disconnected by its BMS or breaker. |
| F58 | BMS communication fault | Battery cable, battery protocol setting, master battery off. |
| F64 | Heat sink temperature high | Ventilation, a hot wall, a closed cupboard. |
F13 after a settings change
F13 is the inverter noting that its operating mode changed. It shows up right after someone edits the system mode or the battery menu, and normally clears within a minute. If it appears at the same time every day without anyone touching anything, a timed setting is the likely trigger.
F18 and F20: current peaks
F18 is on the AC side. A well pump, a compressor or a large inductive load starting on the essential output can draw a peak the inverter will not accept, especially on battery power. F20 is the DC equivalent and often points at the battery: a cell problem, a loose busbar or a battery breaker that is closing badly. Note what was running at the time of the alarm before restarting anything.
F24 on wet mornings
The inverter checks the insulation between the PV strings and earth before it starts. Dew and rain lower that resistance, so F24 at sunrise that disappears once the panels dry is common on older or exposed cabling. If it persists on dry days, a connector or a cable on the roof needs a qualified look. Do not open DC isolators under load to test it.
F35: the grid is gone
F35 simply says there is no grid. During a power cut it is expected, and the essential output should keep running from the battery and the panels. If your neighbours have power and you do not, check the breaker between the meter and the inverter first.
F56 and F58: the battery side
F56 means the DC bus fell too low, which in a home system almost always means the battery: it reached its shutdown level, its BMS opened the contactor, or its breaker tripped. The curve before the alarm tells you which. A slow slide of the state of charge means the battery ran down; a sudden drop to zero means something disconnected it.
F58 is a lost conversation with the battery BMS. The usual suspects are the battery cable in the BMS socket, a battery protocol that no longer matches after a battery swap or a firmware update, and a master battery that was switched off. On multi-battery stacks, the master address matters.
F64: heat
Inverters reduce their power as they warm up and stop when the heat sink gets too hot. A garage that bakes in summer, a south wall or a cupboard without airflow are typical causes. A gradual fall in output power on hot afternoons, before any alarm, is the early sign.
When to call your installer
- Insulation, DC overcurrent or arc fault codes that come back on dry days.
- Any code together with a burning smell, noise or visible damage: switch off as the manual describes and call.
- A code that returns daily and that you cannot link to a setting, a load or the weather.
Why the minute before matters
The code is a snapshot of the moment the inverter gave up. Load, battery voltage and state of charge, PV power and temperature in the minutes before tell you what led there. Sunsynk Monitor keeps those values every few seconds on the box and, if you turn it on, in the free Cloud, so you can look back at the alarm rather than guess. It shows fault and warning codes in plain words, and it never resets or changes anything.
Common questions
Can I clear a Sunsynk fault code myself?
Most codes clear on their own once the cause is gone. Restarting the inverter again and again hides the cause instead of fixing it; find out what happened first.
Is F35 a fault in my inverter?
Rarely. F35 means the inverter sees no grid. Check the supply and the breaker on the grid side before anything else.
Does Sunsynk Monitor reset faults?
No. It only reads the inverter. It shows the code and the values around it, and never writes a setting.