Sunsynk fault codes, and what to check first

A red line on the inverter screen with a code such as F56 tells you that something stopped the inverter, not why. The why is usually in the minute before the alarm. Here are the codes owners meet most, in plain words.

By the Sunsynk Monitor team · 8 November 2026 · 4 min read

In short

  • Most codes describe a condition outside the inverter: no grid, a battery at its limit, too much load, too much heat.
  • Many clear on their own once the cause has gone; a code that comes back daily has a pattern worth finding.
  • Insulation, DC and arc faults involve the roof wiring: leave those to a qualified installer.

Sunsynk hybrids number their alarms with an F and two digits. The list is long, but a handful of codes cover most of what happens in a house. The names below follow the fault table of the Sunsynk hybrid manuals; wording moves a little between models and firmware, so keep the manual for your exact model at hand.

The codes you are most likely to see

CodeMeaningLook at first
F13Working mode changedSomeone changed the system mode, grid type or a battery setting.
F18AC overcurrent (hardware)A motor start or a short on the load side.
F20DC overcurrent (hardware)Battery or PV current peak; often a battery side problem.
F23AC leakage currentAn appliance or wiring fault leaking to earth.
F24DC insulation impedanceDamp or damaged PV cabling, frequent on wet mornings.
F35No AC gridPower cut, grid breaker off, loose grid connection.
F56DC bus voltage too lowBattery at its low limit, or disconnected by its BMS or breaker.
F58BMS communication faultBattery cable, battery protocol setting, master battery off.
F64Heat sink temperature highVentilation, a hot wall, a closed cupboard.

F13 after a settings change

F13 is the inverter noting that its operating mode changed. It shows up right after someone edits the system mode or the battery menu, and normally clears within a minute. If it appears at the same time every day without anyone touching anything, a timed setting is the likely trigger.

F18 and F20: current peaks

F18 is on the AC side. A well pump, a compressor or a large inductive load starting on the essential output can draw a peak the inverter will not accept, especially on battery power. F20 is the DC equivalent and often points at the battery: a cell problem, a loose busbar or a battery breaker that is closing badly. Note what was running at the time of the alarm before restarting anything.

F24 on wet mornings

The inverter checks the insulation between the PV strings and earth before it starts. Dew and rain lower that resistance, so F24 at sunrise that disappears once the panels dry is common on older or exposed cabling. If it persists on dry days, a connector or a cable on the roof needs a qualified look. Do not open DC isolators under load to test it.

F35: the grid is gone

F35 simply says there is no grid. During a power cut it is expected, and the essential output should keep running from the battery and the panels. If your neighbours have power and you do not, check the breaker between the meter and the inverter first.

F56 and F58: the battery side

F56 means the DC bus fell too low, which in a home system almost always means the battery: it reached its shutdown level, its BMS opened the contactor, or its breaker tripped. The curve before the alarm tells you which. A slow slide of the state of charge means the battery ran down; a sudden drop to zero means something disconnected it.

F58 is a lost conversation with the battery BMS. The usual suspects are the battery cable in the BMS socket, a battery protocol that no longer matches after a battery swap or a firmware update, and a master battery that was switched off. On multi-battery stacks, the master address matters.

F64: heat

Inverters reduce their power as they warm up and stop when the heat sink gets too hot. A garage that bakes in summer, a south wall or a cupboard without airflow are typical causes. A gradual fall in output power on hot afternoons, before any alarm, is the early sign.

When to call your installer

  • Insulation, DC overcurrent or arc fault codes that come back on dry days.
  • Any code together with a burning smell, noise or visible damage: switch off as the manual describes and call.
  • A code that returns daily and that you cannot link to a setting, a load or the weather.

Why the minute before matters

The code is a snapshot of the moment the inverter gave up. Load, battery voltage and state of charge, PV power and temperature in the minutes before tell you what led there. Sunsynk Monitor keeps those values every few seconds on the box and, if you turn it on, in the free Cloud, so you can look back at the alarm rather than guess. It shows fault and warning codes in plain words, and it never resets or changes anything.

Common questions

Can I clear a Sunsynk fault code myself?

Most codes clear on their own once the cause is gone. Restarting the inverter again and again hides the cause instead of fixing it; find out what happened first.

Is F35 a fault in my inverter?

Rarely. F35 means the inverter sees no grid. Check the supply and the breaker on the grid side before anything else.

Does Sunsynk Monitor reset faults?

No. It only reads the inverter. It shows the code and the values around it, and never writes a setting.

Sunsynk Monitor box with its colour screen showing solar, battery and grid figures from a Sunsynk inverterRS485 RJ45 socket and USB-C power input of Sunsynk Monitor
The Sunsynk Monitor box, real photos. Size, ports and specifications →
Hands-on

See it on your own system

See your Sunsynk system second by second

Order Sunsynk Monitor now. We prepare and test it for your exact Sunsynk model, and it leaves within 3 working days.

Plug & play: working in about a minute

Order for €59Ships within 3 working days · free cancellation until dispatch
Follow us on FacebookTips, news and real installations from our customers.
Follow